Techbanq

Operational intelligence / Practice deep-dive

OT/IT integration

A safe bridge between the control network and the corporate data foundation.

Architecture, hardware, and protocol work to move OT data into the analytics stack without compromising the control network.

In short

A safe bridge between the control network and the corporate data foundation.

Every industrial intelligence programme depends on a defensible OT/IT bridge. We design and build that bridge to the IEC 62443 segmentation model — data diodes where they belong, gateways where they earn their keep, and a tag dictionary the analytics team can use without re-doing the work.

The data that would make a plant predictive lives on the control network, behind a firewall, on systems designed to never change while a process is running. The analytics, the AI, and the enterprise reporting that would use that data live on the corporate side. Bridging the two is where most industrial AI programmes stall — not because the analytics are hard, but because nobody will compromise the safety and availability of the control system to feed them, and they are right not to.

We design the bridge as a security architecture first. The OT/IT reference architecture is mapped to the IEC 62443 zones and conduits, so the segmentation between the control network and the corporate data foundation is explicit and defensible, and the dataflow runs one way out of the protected zone wherever the risk demands it. This is the design that lets a CISO and a plant manager sign the same diagram.

On that foundation we build the connectivity — gateways and historian integration for OSIsoft PI, Honeywell PHD, AVEVA, and the equivalents — and we impose the discipline that makes the data usable: a tag dictionary and naming standard agreed with operations, so a signal means the same thing on both sides of the bridge. The engagement closes with a security validation report against the segmentation model, so the architecture is not just drawn but tested.

IEC 62443
zone-and-conduit architecture as the design basis
One-way
controlled dataflow out of the protected OT zone
100%
of priority tags governed by a naming standard
Validated
segmentation tested, not just documented

What you walk away with

The pieces we actually ship

  • OT/IT reference architecture mapped to the IEC 62443 zones

  • Gateway and historian connectivity for OSIsoft PI, Honeywell PHD, AVEVA, and equivalent

  • Tag dictionary and naming standard agreed with operations

  • Security validation report against the segmentation model

How we work

From kickoff to handover

01

Zone and conduit mapping

We map the OT/IT reference architecture to the IEC 62443 zones and conduits, making the segmentation between control and corporate networks explicit.

02

Historian connectivity

We build the gateway and historian integration for OSIsoft PI, Honeywell PHD, AVEVA, and equivalents, with dataflow direction controlled by the risk.

03

Tag dictionary and standards

We agree a tag dictionary and naming standard with operations so a signal carries the same meaning on both sides of the bridge.

04

Security validation

We test the architecture against the segmentation model and deliver a validation report, so the design is proven rather than assumed.

Common questions

What buyers ask about this

Your next milestone starts here

A short conversation about the ot/it integration decision in front of you. One hour, no cost, no commitment.

What happens next

  1. 1We reply within one business day.
  2. 2A 30-minute scoping call with a senior consultant.
  3. 3A written proposal with scope, team, and timeline.

Or reach us directly

By submitting this form you agree to our Terms of Use and Privacy Policy.